Export iten: EndNote BibTex

Please use this identifier to cite or link to this item: http://tede.upf.br:8080/jspui/handle/tede/2325
Full metadata record
DC FieldValueLanguage
dc.creatorLesniesky, Roberto Junior Gaspar-
dc.creator.Latteshttp://lattes.cnpq.br/1492203356343737por
dc.contributor.advisor1Haupt, William-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3288923141358212por
dc.date.accessioned2022-10-25T17:57:08Z-
dc.date.issued2021-12-10-
dc.identifier.citationLESNIESKY, Roberto Junior Gaspar . Desenvolvimento de equipamento para ensaio de tribocorrosão e análise de revestimentos superficiais em aço inoxidável super duplex SAF 2507 depositados por processo TIP/TIG em base de aço ASTM A36. 2021. 80 f. Dissertação (Mestrado em Projeto e Processos de Fabricação) - Universidade de Passo Fundo, Passo Fundo, RS, 2021.por
dc.identifier.urihttp://tede.upf.br:8080/jspui/handle/tede/2325-
dc.description.resumoEste trabalho apresenta o projeto de um tribômetro linear para análises de revestimentos de ligas metálicas de alta resistência à corrosão, validado analisando o aço inoxidável superduplex SAF 2507. O ensaio baseia-se na corrosão da superfície do material imerso em meio NaCl na concentração de 1 mol/L submetido a um potencial de corrente elétrica controlada por um potenciostato de acordo com normativa ASTM G61. O estudo avaliou depósitos da liga superduplex SAF 2507 em chapas base de aço carbono ASTM A36 depositados pelo processo TIP/TIG com frequências de oscilação do eletrodo de adição de 5 Hz, 10 Hz e 15 Hz. O estudo desenvolveu uma máquina para geração de atrito com objetivo de avaliar os efeitos da tribocorrosão durante o ensaio de voltametria e comparar a ensaios de voltametria realizados em amostras do mesmo material com superfície polida. As aplicações destes revestimentos abrangem indústrias de óleo e gás, química e indústrias de papel e celulose. Os resultados e análises compararam a microestrutura e características pós processamento do material analisado, os efeitos de corrosão por pites e frestas na microestrutura foram analisados através de microscopia, destacando-se os efeitos do atrito na ruptura de camada, formando pites na região de atrito e consequentemente reduzindo a resistência a corrosão. É pertinente destacar o adequado funcionamento eletromecânico do equipamento, bem como a instrumentação acoplada, permitindo controle de parâmetros de processo, o equipamento foi submetido a patente de invenção.por
dc.description.abstractThis work presents the design of a linear tribometer for the analysis of high corrosion resistance metallic alloy coatings, validated by analyzing the SAF 2507 superduplex stainless steel. The test is based on the surface corrosion of the material immersed in NaCl medium at a concentration of 1 mol/L subjected to an electric current potential controlled by a potentiostat in accordance with ASTM G61. The study evaluated SAF 2507 superduplex alloy deposits on ASTM A36 carbon steel base plates deposited by the TIP/TIG process with addition electrode oscillation frequencies of 5Hz, 10Hz and 15Hz. The study developed a machine to generate friction in order to evaluate the effects of tribocorrosion during the voltammetry test and compare to voltammetry tests performed on samples of the same material with a polished surface. Applications for these coatings span the oil and gas, chemical and pulp and paper industries. The results and analyzes compared the microstructure and post-processing characteristics of the material analyzed, the effects of pitting and crevice corrosion on the microstructure were analyzed by microscopy, highlighting the effects of friction on layer rupture, forming pits in the friction region and consequently reducing corrosion resistance. It is pertinent to highlight the proper electromechanical functioning of the equipment, as well as the coupled instrumentation, allowing control of process parameters, the equipment was submitted to a patent of invention.eng
dc.description.provenanceSubmitted by Jucelei Domingues (jucelei@upf.br) on 2022-10-25T17:57:08Z No. of bitstreams: 1 2021RobertoJuniorGLesniesky.pdf: 5575655 bytes, checksum: 73e6d8c5749b4044cba46fe6d770891c (MD5)eng
dc.description.provenanceMade available in DSpace on 2022-10-25T17:57:08Z (GMT). No. of bitstreams: 1 2021RobertoJuniorGLesniesky.pdf: 5575655 bytes, checksum: 73e6d8c5749b4044cba46fe6d770891c (MD5) Previous issue date: 2021-12-10eng
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade de Passo Fundopor
dc.publisher.departmentFaculdade de Engenharia e Arquitetura – FEARpor
dc.publisher.countryBrasilpor
dc.publisher.initialsUPFpor
dc.publisher.programPrograma de Pós-Graduação em Projeto e Processos de Fabricaçãopor
dc.rightsAcesso Abertopor
dc.subjectProcessos de fabricaçãopor
dc.subjectAço - Corrosãopor
dc.subjectAço inoxidávelpor
dc.subjectDesgaste mecânicopor
dc.subject.cnpqENGENHARIAS::ENGENHARIA CIVILpor
dc.titleDesenvolvimento de equipamento para ensaio de tribocorrosão e análise de revestimentos superficiais em aço inoxidável super duplex SAF 2507 depositados por processo TIP/TIG em base de aço ASTM A36por
dc.typeDissertaçãopor
Appears in Collections:Programa de Pós-Graduação em Projeto e Processos de Fabricação

Files in This Item:
File Description SizeFormat 
2021RobertoJuniorGLesniesky.pdfDissertação Roberto Junior Gaspar Lesniesky5.44 MBAdobe PDFView/Open ???org.dspace.app.webui.jsptag.ItemTag.preview???


Items in TEDE are protected by copyright, with all rights reserved, unless otherwise indicated.