???metadata.dc.description.resumo???: | Toda edificação está sujeita a ação do vento condizente com sua zona de imersão, ou seja, dependendo das condições do entorno e sua geometria será a magnitude da força a ela imposta. A pressão externa, importante para desenvolver projetos estruturais, é essencialmente dependente das propriedades da turbulência do escoamento e, sobretudo, da velocidade. São os coeficientes de pressão externas que relacionam a força atuante no sólido imerso ao fluxo, com a força dinâmica do vento a barlavento da edificação sendo este fadado a rugosidade, incidência de vento e forma da edificação. Logo, através dos coeficientes de pressão que se determina o quanto da pressão dinâmica do vento será tomada como esforço na análise estrutural. Os telhados quatro águas começaram a serem estudados após análises pós furacão revelarem que algumas residências menos danificadas ou intactas possuírem este tipo de cobertura. Doravante, esta tipologia ficou conhecida pela sua resistência comprovada defronte a ventos extremos, sendo comumente utilizado na construção civil. No Brasil, a norma ABNT NBR 6123:1988 que preconiza o cálculo das ações devidas ao vento em edificações, não contempla telhado quatro águas em suas premissas. Logo, objetiva-se, a partir de simulações computational fluid dynamics (CFD) avaliando diferentes proporções geométricas e inclinações de coberturas variadas pode-se mapear o comportamento do vento determinar subsídios de cálculo para seu adequado dimensionamento. Para tal, fora reproduzidos ensaios de estudos consolidados afim de validar a metodologia numérica e em contrapartida compara-la com códigos ASCE-7:2022, National Building Code of Canada 2005, EUROCODE-1991-1-4:2010 e AS/NZS 1170.2.2011:2017 detentores de grande renome internacional. Ao findar do processo propõem-se uma contribuição inicial de ábaco de coeficientes de pressão externa para cobertura quatro águas para auxiliar engenheiros estruturais na determinação de ações do vento junto a essa tipologia de cobertura. |
Abstract: | Every building is subject to wind action consistent with its immersion zone, that is, depending on the surrounding conditions and its geometry will be the magnitude of the force imposed on it. The external pressure, important for developing structural projects, is essentially dependent on the flow turbulence properties and, above all, on the velocity. They are the external pressure coefficients that relate the force acting on the solid immersed to the flow, with the dynamic force of the wind to the windward side of the building, which is bound to the roughness, wind incidence and shape of the building. Therefore, through the pressure coefficients it is determined how much of the dynamic pressure of the wind will be taken as effort in the structural analysis. The hip roofs began to be studied after post-hurricane analyzes revealed that some less damaged or intact homes had this type of coverage. Henceforth, this typology became known for its proven resistance to extreme winds, being commonly used in civil construction. In Brazil, the ABNT NBR 6123:1988 standard, which recommends the calculation of actions due to wind in buildings, does not include a hipped roof in its premises. Therefore, the objective is, from computational fluid dynamics (CFD) simulations, evaluating different geometric proportions and slopes of different roofs, it is possible to map the wind behavior to determine calculation subsidies for its adequate sizing. To this end, essays from consolidated studies were reproduced in order to validate the numerical methodology and, on the other hand, compare it with codes ASCE-7:2022, National Building Code of Canada 2005, EUROCODE-1991-1- 4:2010 and AS/NZS 1170.2 .2011:2017 holders of great international reputation. At the end of the process, an initial contribution of an abacus of external pressure coefficients for hip roofs is proposed to assist structural engineers in the determination of wind actions with this roof typology. |
Keywords: | Telhados - Aerodinâmica Telhados - Projetos e construção Pressão do vento |
???metadata.dc.subject.cnpq???: | ENGENHARIAS::ENGENHARIA CIVIL |
???metadata.dc.language???: | por |
???metadata.dc.publisher.country???: | Brasil |
Publisher: | Universidade de Passo Fundo |
???metadata.dc.publisher.initials???: | UPF |
???metadata.dc.publisher.department???: | Faculdade de Engenharia e Arquitetura – FEAR |
???metadata.dc.publisher.program???: | Programa de Pós-Graduação em Engenharia Civil e Ambiental |
Citation: | POL, William de Oliveira. Avaliação de coeficientes aerodinâmicos de pressão em telhados quatro águas. 2022. 109 f. Dissertação (Mestrado em Engenharia Civil e Ambiental) - Universidade de Passo Fundo, Passo Fundo, RS, 2022. |
???metadata.dc.rights???: | Acesso Aberto |
URI: | http://tede.upf.br:8080/jspui/handle/tede/2497 |
Issue Date: | 8-Apr-2022 |
Appears in Collections: | Programa de Pós-Graduação em Engenharia Civil e Ambiental |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
2022WilliamdeOliveiraPol.pdf | Dissertação de William de Oliveira Pol | 6.33 MB | Adobe PDF | View/Open ???org.dspace.app.webui.jsptag.ItemTag.preview??? |
Items in TEDE are protected by copyright, with all rights reserved, unless otherwise indicated.