???jsp.display-item.social.title??? |
|
Please use this identifier to cite or link to this item:
http://tede.upf.br:8080/jspui/handle/tede/235
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.creator | Silvani, Marinês | - |
dc.creator.Lattes | http://lattes.cnpq.br/8429844249283469 | por |
dc.contributor.advisor1 | Paluch, Mario José | - |
dc.contributor.advisor-co1 | Hemkemeier, Marcelo | - |
dc.contributor.advisor-co1Lattes | http://lattes.cnpq.br/1369101484238907 | por |
dc.date.accessioned | 2018-01-10T17:55:30Z | - |
dc.date.available | 2009-09-09 | - |
dc.date.issued | 2005-04-30 | - |
dc.identifier.uri | http://10.0.217.128:8080/jspui/handle/tede/235 | - |
dc.description.resumo | A ventilação natural deve ser a primeira alternativa a ser estudada no projeto de ambientes industriais, o que se deve a uma série de fatores relacionados a custos e exigências de mercado. Os métodos de cálculo do sistema de ventilação natural de uma edificação consideram duas situações meteorológicas: existência ou não de vento. Na primeira situação a ventilação é promovida pelo efeito do vento e pelo denominado efeito chaminé. Na segunda situação, ou seja, quando não há vento, a ventilação é provocada unicamente pelo efeito da convecção natural, ou seja, o efeito chaminé. Na bibliografia técnica nacional e intecnacional são apresentadas diferentes equações para efetuar o demensionamento do sistema de ventilação natural em pavilhões industriais. Os resultados apresentados neste trabalho indicam que os modelos teóricos considerados, apresentam uma dispersão de resultados compatíveis com o bom exercício da engenharia | por |
dc.description.abstract | The natural ventilation must be the first alternative to be studied for industrial environment design, and this fact is due to several reasons related to costs and market requirements. The design methods for natural ventilation system of a building take into consideration meteorological situations: the existence or the non-existence of wind. In the first situation, the ventilation is promoted by the wind effect and by the so-called stack effect. In the second situation, that is, when there is no wind, the ventilation only exists by the effect of natural convection, that is, the stack effect. In the Brazilian, as well as in the international technical publications, different equations are presented to perform the natural ventilation calculation for industrial buildings. According to Frota (1989), the use of those models leads to several results. However, the results showed in this paper indicate that the considered theoretical models show results that are compatible with the good exercise of the Engineering | eng |
dc.description.provenance | Made available in DSpace on 2018-01-10T17:55:30Z (GMT). No. of bitstreams: 1 2005MarinesSilvani.pdf: 4779525 bytes, checksum: 786124b04cdde4ffcd6db18fc36f5d21 (MD5) Previous issue date: 2005-04-30 | eng |
dc.format | application/pdf | por |
dc.language | por | por |
dc.publisher | por | |
dc.publisher.department | Engenharias | por |
dc.publisher.country | por | |
dc.publisher.initials | por | |
dc.publisher.program | Programa de Pós-Graduação em Engenharia | por |
dc.rights | Acesso Aberto | por |
dc.subject | Ventilação | por |
dc.subject | Edifícios industriais | por |
dc.subject | Construção civil | por |
dc.subject | Ventilation | eng |
dc.subject | Industrial buildings | eng |
dc.subject | Building | eng |
dc.subject.cnpq | CNPQ::ENGENHARIAS::ENGENHARIA CIVIL::CONSTRUCAO CIVIL | por |
dc.title | Subsídios para o projeto da ventilação natural em pavilhões industriais | por |
dc.type | Dissertação | por |
Appears in Collections: | Programa de Pós-Graduação em Engenharia Civil e Ambiental |
Files in This Item:
File | Size | Format | |
---|---|---|---|
2005MarinesSilvani.pdf | 4.67 MB | Adobe PDF | View/Open ???org.dspace.app.webui.jsptag.ItemTag.preview??? |
Items in TEDE are protected by copyright, with all rights reserved, unless otherwise indicated.