Export iten: EndNote BibTex

Please use this identifier to cite or link to this item: http://tede.upf.br:8080/jspui/handle/tede/218
Full metadata record
DC FieldValueLanguage
dc.creatorZanchetta, Graziele Simone Boscatto-
dc.creator.Latteshttp://lattes.cnpq.br/4393022282363715por
dc.contributor.advisor1Escosteguy, Pedro Alexandre Varella-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3761510596068261por
dc.date.accessioned2018-01-10T17:55:27Z-
dc.date.available2009-08-20-
dc.date.issued2007-04-03-
dc.identifier.urihttp://10.0.217.128:8080/jspui/handle/tede/218-
dc.description.resumoApós um lixão ser desativado, o potencial de contaminação pode se estender por várias décadas, sendo exigência dos órgãos ambientais a recuperação dessa área. Como a atividade dos RSU tem prazo finito e o solo tem capacidade de atenuação atuando como barreira de proteção, essa recuperação pode ser desnecessária. O objetivo dessa pesquisa foi o de avaliar o grau de inertização dos resíduos sólidos (RSU) de um lixão, desativado há mais de 3 anos, e a contaminação desse local para verificar a necessidade de recuperação da área. Foram caracterizados os resíduos sólidos aterrados, o solo, as plantas, as águas superficiais e subterrâneas e foi verificada a capacidade de atenuação do solo, em relação a metais. O monitoramento das águas superficiais e subterrâneas incluiu análises físico-químicas e microbiológicas, durante o período de janeiro a setembro de 2006. A caracterização dos resíduos foi realizada através da composição gravimétrica e dos ensaios de lixiviação, solubilização, teste de respirometria e análise físico-químico. O solo e as plantas analisados, dentro e fora do lixão, foram submetidos a análises de nutrientes, incluindo metais, para verificar a capacidade de retenção e o grau de toxicidade. A capacidade de atenuação do solo foi verificada em equipamento de coluna, analisando os metais, antes e após a percolação de solução contendo os metais analisados. Os resultados, em geral, indicaram que a maioria dos resíduos aterrados é inerte, sendo que 80 % das amostras analisadas no teste de respirometria são estáveis e os resíduos sólidos urbanos aterrados são classificados como Classe IIB e inertes. O solo da área apresenta alta capacidade de retenção de cádmio, além de zinco e cobre, mas têm capacidade intermediária de retenção de chumbo e manganês. Conclui-se que a contaminação da área está estagnada, mas há contaminação de nitratos, coliformes, sólidos totais dissolvidos, fósforo, ferro e manganês nas águas subterrâneas à jusante, além da contaminação de ferro, manganês, zinco e cobre no solo e plantaspor
dc.description.abstractAfter a dump deactivation, the contamination potential may extend for several decades, being a requirement of the environmental agencies the recovery of this area. Since the urban solid wastes activity has finite period and soil has an attenuation capacity acting as a protection barrier, this recovery may be unnecessary. The research objective was to evaluate the inertization degree of solid wastes from a dump inactive for over three years and the site contamination to verify the need of recovering the area. Were characterized deposited solid wastes, soil, plants, superficial and underground waters and it was verified soil attenuations capacity regarding metals. Superficial and underground waters monitoring included physical-chemical and microbiological analyses, during the period from January to September 2006. Wastes characterization was accomplished through gravimetric composition, lixiviation and solubilization analyses, respirometry test and physical-chemical analilysis. Analyzed soil and plants inside and out of the dump, were submitted to nutrients analyses including metals to verify retention capacity and toxicity degree. Soil attenuation ability was verified in column equipment analyzing metals before and after the solution containing the analyzed metals percolation. In general, results indicated that most of disposed wastes are inert, where 80% of analyzed samples in respirometry test are stable and disposed urban solid wastes are classified as Class IIB and inert. Site soil presents high retention ability of cadmium, zinc and copper but it shows intermediary retention capacity of lead and manganese. It follows that site contamination is stagnant but there s contamination in underground waters beyond the dump by nitrates, coliforms, total dissolved solids, phosphorus, iron and manganese, besides iron, manganese, zinc and copper contamination in soil and plantseng
dc.description.provenanceMade available in DSpace on 2018-01-10T17:55:27Z (GMT). No. of bitstreams: 1 2007GrazieleZanchetta.pdf: 2378727 bytes, checksum: 5c0461e66a6a6ec3cd626e208f1e3dbe (MD5) Previous issue date: 2007-04-03eng
dc.formatapplication/pdfpor
dc.languageporpor
dc.publisherpor
dc.publisher.departmentEngenhariaspor
dc.publisher.countrypor
dc.publisher.initialspor
dc.publisher.programPrograma de Pós-Graduação em Engenhariapor
dc.rightsAcesso Abertopor
dc.subjectLixo - Eliminação - Lagoa Vermelha (RS)por
dc.subjectSolos - Poluiçãopor
dc.subjectÁgua - Poluiçãopor
dc.subjectPoluição - Controlepor
dc.subjectSoil pollutioneng
dc.subjectPollutioneng
dc.subjectRefuse and refuse disposaleng
dc.subjectWatereng
dc.subject.cnpqCNPQ::ENGENHARIAS::ENGENHARIA SANITARIA::SANEAMENTO AMBIENTAL::CONTROLE DA POLUICAOpor
dc.titleAvaliação do grau de poluíção do solo, águas, plantas e resíduos sólidos do lixão Linha Rincão do Engenho de Lagoa Vermelha, RSpor
dc.typeDissertaçãopor
Appears in Collections:Programa de Pós-Graduação em Engenharia Civil e Ambiental

Files in This Item:
File SizeFormat 
2007GrazieleZanchetta.pdf2.32 MBAdobe PDFView/Open ???org.dspace.app.webui.jsptag.ItemTag.preview???


Items in TEDE are protected by copyright, with all rights reserved, unless otherwise indicated.