Export iten: EndNote BibTex

Please use this identifier to cite or link to this item: http://tede.upf.br:8080/jspui/handle/tede/1994
???metadata.dc.type???: Dissertação
Title: Diferenciação oxidativa em dispositivos temporários de ancoragem de titânio e aço
Other Titles: Oxidative differentiation in temporary anchoring devices of titanium and steel
???metadata.dc.creator???: Picolo, Thiago Oszika 
???metadata.dc.contributor.advisor1???: Trentin, Micheline Sandini
???metadata.dc.contributor.advisor-co1???: Farina, Ana Paula
???metadata.dc.description.resumo???: A corrosão dos mini-implantes ortodônticos ou dispositivos de ancoragem temporários (DATs) tem sido proposta como um fator contribuinte para a inflamação dos tecidos bucais, que por sua vez contribui para o sucesso clínico dos mini-implantes (KNUTSON, 2013). Dessa forma, faz-se necessária a utilização de um material que apresente maior resistência que o Titânio e suas ligas (SQUEFF et al., 2008; CHANG et al., 2015). Atualmente, os DATs de aço inoxidável para procedimento de ancoragem ortodôntica apresentam um alto índice de sucesso, o que tem levado a uma grande procura pelos profissionais da área (CHANG et al., 2015). Este trabalho testou a hipótese de que os dispositivos de ancoragem temporários (DATs) fabricados de Aço 316L são mais resistentes à corrosão mesmo em meio com flúor, do que os DATs fabricados apartir de ligas de titânio. Para tanto foram realizadas medições eletroquímicas em Potenciostato. Materiais e Métodos: Quatro amostras de cada material foram testadas em cada conjunto de teste, a formulação artificial de saliva de Fusayama foi usada como eletrólito solução neste estudo de corrosão in vitro, sem flúor em sua composição e em segundo momento com a concentração de 1500ppM de flúor em sua composição. No teste, uma polarização catódica foi então realizada aumentando essa voltagem por 5 minutos ou até que se obtivessem os pitins de corrosão. Em saliva artificial contendo até 1500 ppmF- para cada material e, repetido esse teste com novas amostras de cada material em solução de saliva artificial sem a presença de flúor. Resultados: Os resultados de escala de corrente de indução foram inseridos no software OriginPro8 para confecção dos gráficos de valores. Dentre todas as ligas metálicas utilizadas atualmente a liga de Ti6Al4V apresentou uma boa resistência à corrosão em saliva artificial. Entretanto, a corrosão destas ligas ocorre em contato com altas concentrações de flúor, diferentemente da liga de Aço 316L que além da corrosão faz a passivação da superfície.
Abstract: Corrosion of orthodontic mini-implants or temporary anchoring devices (TADs) has been proposed as a contributing factor to inflammation of oral tissues, which in turn contributes to the clinical success of mini-implants (KNUTSON, 2013). Thus, it is necessary to use a material that presents greater resistance than Titanium and its alloys (SQUEFF et al., 2008; CHANG et al., 2015). Currently, stainless steel TADs for orthodontic anchorage procedures have a high success rate, which has led to a high demand for professionals in the area (CHANG et al., 2015). This study tested the hypothesis that temporary anchoring devices (TADs) made of 316L steel are more resistant to corrosion even in the fluorine environment, than DATs manufactured in addition to titanium alloys, for both potentiostat electrochemical meters. Materials and Methods: Four pieces of each material were tested in each test set, an application of Fusayama artificial saliva was used as an electrolytic solution in this study of corrosion in vitro, without flowing in its composition and in the second moment with 1500ppM of fluorine in its composition. In the test, a cathodic polarization was performed after the activation of this voltage for 5 minutes or until the corrosion pins were obtained. In artificial saliva, containing up to 1500ppmF- for each material and, this test was repeated with new samples of each material in artificial saliva solution without fluoride. Results: The results of the induction current scale were entered without OriginPro8 software for making value graphs. All metal alloys currently used in the Ti6Al4V alloy showed good resistance to corrosion in artificial saliva. However, the corrosion of these alloys occurs in contact with high temperatures, unlike 316L steel alloy, which in addition to corrosion makes the surface passivated.
Keywords: Implantes dentários
Odontologia
Ortodontia
???metadata.dc.subject.cnpq???: CIENCIAS DA SAUDE::ODONTOLOGIA
???metadata.dc.language???: por
???metadata.dc.publisher.country???: Brasil
Publisher: Universidade de Passo Fundo
???metadata.dc.publisher.initials???: UPF
???metadata.dc.publisher.department???: Faculdade de Odontologia – FO
???metadata.dc.publisher.program???: Programa de Pós-Graduação em Odontologia
Citation: PICOLO, Thiago Oszika. Diferenciação oxidativa em dispositivos temporários de ancoragem de titânio e aço. 2020. 61 f. Dissertação (Mestrado em Odontologia) - Universidade de Passo Fundo, Passo Fundo, RS, 2020.
???metadata.dc.rights???: Acesso Aberto
URI: http://tede.upf.br:8080/jspui/handle/tede/1994
Issue Date: 16-Apr-2020
Appears in Collections:Programa de Pós-Graduação em Odontologia

Files in This Item: