DC FieldValueLanguage
dc.creatorSilva, Felipe Leite-
dc.creator.Latteshttp://lattes.cnpq.br/3166948586423690por
dc.contributor.advisor1Chamberlain Pravia, Zacarias Martin-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/9385545081914644por
dc.date.accessioned2018-06-13T18:03:36Z-
dc.date.issued2016-05-06-
dc.identifier.citationSILVA, Felipe Leite. Avaliação do comportamento estrutural de ligações viga-coluna parafusadas com cantoneiras duplas na alma. 2016. 113 f. Dissertação (Mestrado em Engenharia Civil e Ambiental) - Universidade de Passo Fundo, Passo Fundo, RS, 2016.por
dc.identifier.urihttp://tede.upf.br/jspui/handle/tede/1421-
dc.description.resumoNo projeto de estruturas de aço, as ligações viga-coluna do tipo dupla cantoneira parafusada, ou ligação cantoneira parafusada-parafusada (LCPP), usualmente são consideradas flexíveis. A partir dessa hipótese simplificatória, na prática podem surgir nas colunas esforços de flexão não considerados, assim como na viga menores momentos fletores e deslocamentos que aqueles estimados em projeto. O escopo deste trabalho é determinar os valores de rigidez rotacional de uma LCPP sob a aplicação de cargas no intervalo elástico. Foram realizados: ensaios experimentais, simulações numéricas via método dos elementos finitos (MEF) e estimativas de rigidez inicial segundo equações disponíveis nas referências consultadas, para a LCPP; ensaios experimentais e estimativas analíticas de deslocamentos e momentos fletores para viga simplesmente apoiada; ensaios experimentais e simulações numéricas via MEF para viga ligada com pino. Este trabalho vem complementar os já existentes, ao modelar numérica e experimentalmente a viga com seus dois extremos conectados, e não como a maioria das pesquisas, que avaliam apenas a ligação. Os resultados mostram, para o estudo aqui desenvolvido, uma redução de até 18% do momento fletor no centro do vão da viga em relação à viga simplesmente apoiada, permitindo que essa ligação possa ser classificada como semirrígida de acordo com a ABNT NBR 8800.por
dc.description.abstractWhen modeling steel structures, some connections are considered flexible. One of them is double angle with bolts in both sides of the elements that are connected. This hypothesis simplifies the whole structural analysis, but in some cases bending moments could be transmitted from beams to columns with that kind of connections. The issue of this work is to estimate rotational stiffness for a double-web angle connection with bolts. For this objective, numerical and experimental simulations were developed, first with a simple supported beam and a pinned beam has a reference, and after with beam with double-angle connections. This research adds significant results to others in the references, because both modeling, experimental and numerical, were developed with the beam with both ends considered. Results shows an 18 % of bending moment reduction compared to the model of simple-supported beam. Additionally, that kind of connection could be classified as semi-rigid by the Brazilian standard ABNT NBR 8800.eng
dc.description.provenanceSubmitted by Aline Rezende (alinerezende@upf.br) on 2018-06-13T18:03:36Z No. of bitstreams: 1 2016FelipeLeiteSilva.pdf: 2660828 bytes, checksum: 46d2e4ac6807b65559625a2c19c75e4c (MD5)eng
dc.description.provenanceMade available in DSpace on 2018-06-13T18:03:36Z (GMT). No. of bitstreams: 1 2016FelipeLeiteSilva.pdf: 2660828 bytes, checksum: 46d2e4ac6807b65559625a2c19c75e4c (MD5) Previous issue date: 2016-05-06eng
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade de Passo Fundopor
dc.publisher.departmentFaculdade de Engenharia e Arquitetura – FEARpor
dc.publisher.countryBrasilpor
dc.publisher.initialsUPFpor
dc.publisher.programPrograma de Pós-Graduação em Engenharia Civil e Ambientalpor
dc.rightsAcesso Abertopor
dc.subjectVigamento (Construção civil)por
dc.subjectLigas (Metalurgia)por
dc.subjectAço - Estruturaspor
dc.subjectPórticos estruturaispor
dc.subject.cnpqENGENHARIA CIVIL::CONSTRUCAO CIVILpor
dc.titleAvaliação do comportamento estrutural de ligações viga-coluna parafusadas com cantoneiras duplas na almapor
dc.title.alternativeEvaluation of the structural behavior of bolted beam-column connections with double angles in the coreeng
dc.typeDissertaçãopor
Appears in Collections:Programa de Pós-Graduação em Engenharia Civil e Ambiental