???jsp.display-item.social.title??? |
|
Please use this identifier to cite or link to this item:
http://tede.upf.br:8080/jspui/handle/tede/1383
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.creator | Rodrigues, Eduardo dos Santos | - |
dc.creator.Lattes | http://lattes.cnpq.br/4308462495342121 | por |
dc.contributor.advisor1 | Linden, Maria Salete Sandini | - |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/1053417971561321 | por |
dc.date.accessioned | 2018-05-30T20:22:47Z | - |
dc.date.issued | 2016-05-31 | - |
dc.identifier.citation | RODRIGUES, Eduardo dos Santos. Distribuição de tensões entre parafusos protéticos de implante cone morse e hexágono externo: análise de elementos finitos. 2016. 102 f. Dissertação (Mestrado em Ciência e Tecnologia de Alimentos) - Universidade de Passo Fundo, Passo Fundo, RS, 2016. | por |
dc.identifier.uri | http://tede.upf.br/jspui/handle/tede/1383 | - |
dc.description.resumo | O objetivo deste trabalho foi analisar a distribuição de tensões dos parafusos protéticos de Implante Hexágono Externo (HE) e Implante Cone Morse (CM) com diferentes pré-cargas. Utilizando-se dois modelos 3D para o estudo: MHE - Modelo do Implante HE, e MCM ¿ Modelo do Implante CM, compostos por implante, UCLA antirotacional e parafuso protético. Em cada modelo, simulouse duas situações: valor de pré-carga com o torque recomendado pelo fabricante para o parafuso protético (MHE1 e MCM1); e 10 Ncm acima do torque recomendado (MHE2 e MCM2). Obtendo os valores de pré-carga, 243,18N, 229,71N, 324,24N e 344,57, respectivamente. Os resultados foram representados pela análise de tensão equivalente Von Mises, de forma que as roscas dos parafusos protéticos foram os locais que apresentaram as tensões máximas, porém a tensão máxima do modelo MCM2 ultrapassou o limite de escoamento do material na região da raiz entre o 1º e 2º filete. Concluindo que a utilização de torques acima do recomendado pelo fabricante pode ocasionar deformações plásticas nas roscas do implante cone-morse, e que a aplicação de torques elevados é menos prejudicial para o implante hexágono externo. | por |
dc.description.abstract | This three-dimensional finite element study observed the stress distribution characteristics of prosthetic screws on External Hexagon Implant (HE) and Morse Taper Implant (CM) with different preloads. Using two models for the study: MHE - HE implant model, and MCM -CM implant model, compounds by implant, abutment and abutment screw. In each model was evaluated two situations: preload value using the torque recommended by the manufacturer for the prosthetic screw (MHE1 and MCM1); and 10 Ncm above the recommended torque (MHE2 and MCM2). Finding the preload values respectively 243,18N, 229,71N, 324,24N and 344.57. The regions with the highest von Mises stress results were at the bottom of the initial two threads in contact of all models, however the maximum stress on MCM2 model were higher than the yield strength of abutment screw material. In conclusion, the use of torques above the recommended can cause plastic deformation in the threads of morse taper implant. Elevated torques are harmful to morse taper implant than to external hexagon implant. | eng |
dc.description.provenance | Submitted by Aline Rezende (alinerezende@upf.br) on 2018-05-30T20:22:47Z No. of bitstreams: 1 2017EduardodosSantosRodrigues.pdf: 1147987 bytes, checksum: 6faf4ee0257e5ca9a899b87d8460f6a8 (MD5) | eng |
dc.description.provenance | Made available in DSpace on 2018-05-30T20:22:47Z (GMT). No. of bitstreams: 1 2017EduardodosSantosRodrigues.pdf: 1147987 bytes, checksum: 6faf4ee0257e5ca9a899b87d8460f6a8 (MD5) Previous issue date: 2016-05-31 | eng |
dc.format | application/pdf | * |
dc.language | por | por |
dc.publisher | Universidade de Passo Fundo | por |
dc.publisher.department | Faculdade de Agronomia e Medicina Veterinária – FAMV | por |
dc.publisher.country | Brasil | por |
dc.publisher.initials | UPF | por |
dc.publisher.program | Programa de Pós-Graduação em Ciência e Tecnologia de Alimentos | por |
dc.rights | Acesso Aberto | por |
dc.subject | Implantes dentários | por |
dc.subject | Titânio | por |
dc.subject | Prótese dentária | por |
dc.subject.cnpq | CIENCIAS DA SAUDE::ODONTOLOGIA | por |
dc.title | Distribuição de tensões entre parafusos protéticos de implante cone morse e hexágono externo: análise de elementos finitos | por |
dc.title.alternative | Distribution of stresses between cone morse and external hexagon implant prosthetic screws: finite element analysis | eng |
dc.type | Dissertação | por |
Appears in Collections: | Programa de Pós-Graduação em Odontologia |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
2017EduardodosSantosRodrigues.pdf | Dissertação Eduardo dos Santos Rodrigues | 1.12 MB | Adobe PDF | View/Open ???org.dspace.app.webui.jsptag.ItemTag.preview??? |
Items in TEDE are protected by copyright, with all rights reserved, unless otherwise indicated.